Bridge Module 10/100Base-TX/100Base-FX Page 6/7
MICROSENS GmbH & Co. KG - Küferstr. 16 - D-59067 Hamm - Tel. +49 (0)2381/9452-0 - Fax -100 - www.microsens.com
7 – 9 Off
10 ON: Configuration by Management
11 Off
12 Off
Additional the bandwidth of the user data can be limited symmetric. By the software
management it is possible to limit the bandwidth in steps of 32 kbps or by the DIP-
switches in the following steps:
DIP-switch
7 8 9
Max. data rate between the ports (each direction)
0 0 0 100 Mbps (100Base-TX), no limitation
0 0 1 75 Mbps
0 1 0 50 Mbps
0 1 1 34 Mbps (E3)
1 0 0 20 Mbps
1 0 1 10 Mbps (10Base-T)
1 1 0 8 Mbps
1 1 1 2 Mbps (E1)
0 = Switch OFF, 1 = Switch ON
Link Trough / ALM
The link status of each segment is forwarded, that means a missing link on the input
side also the link signal of the corresponding output side is switched off physically.
Attention: If activated by the DIP-switches there is no link signal generated by the
bridge in idle state. This is no malfunction!
Port x Port x
RX RXTX TX
TX TXRX RX
Port y Port y
No Link Link
Link Thr ough ON Link Through OFF
If ALM (Advanced Link Monitoring) is activated the same fiber port is not sending a link
signal if he does not receive a link signal (Link Down). This ensures that both directions
of the fiber line, TX and RX are having the same link status.
Por t x Port x
TX TX
RX RX
Port y Po rt y
No Link Link
ALM ON ALM OFF