Microsens RS232 Especificações Página 16

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 36
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 15
4 Port Industrial Device Server Manual page 16/36
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Configure serial port
Serial Settings
The following table describes the labels in this screen.
Label
Description
Port Alias
Remark the port to hint the connected device.
Interface
RS232 / RS422 / RS485(2-wires) / RS485(4-wires)
Baud rate
110bps/300bps/1200bps/2400bps/4800bps/9600bps/19200bps/
38400bps/57600bps/115200bps/230400bps/460800bps
Data Bits
5, 6, 7, 8
Stop Bits
1, 2 (1.5)
Parity
No, Even, Odd, Mark, Space
Flow Control
No, XON/XOFF, RTS/CTS, DTR/DSR
Performance
Throughput: This mode optimized for highest transmission speed.
Latency: This mode optimized for shortest response time.
Serial to
Ethernet
Delimiter:
You can define max. 4 delimiters (00~FF, Hex) for each way. The data will be
hold until the delimiters are received or the option Flush Serial to Ethernet
data buffer” times out. 0 means disable. Factory default is 0.
Flush Data Buffer After:
The received data will be queuing in the buffer until all the delimiters are
matched. When the buffer is full (4K Bytes) or after "flush S2E data buffer"
timeout the data will also be sent. You can set the time from 0 to 65535
seconds.
Vista de página 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 35 36

Comentários a estes Manuais

Sem comentários