19'' 6U Chassis
Overview
6U Chassis is a part of MICROSENS 10G Transport Platform, a high performance and
flexible carrier-class transmission system. The 10G Transport Platform enables increasing
transport capacities in CWDM, DWDM and SDH networks. The use of wide range TDM
modules permits to reduce the number of necessary wavelengths and to decrease the
overall cost of the application. Ethernet over SDH modules enable using existing
SONET/SDH infrastructure for IP transmission.
The general features of the system:
19“ 2U Chassis with 5 module slots and management card
Max. 5x single size modules i.e. 2x double size + 1x single size module
Hot swappable modules & power supplies
Redundant power supplies with -48 VDC input (opt. 230 VAC)
Exchangeable air- and filter module
Wide range of functional xWDM and TDM modules available
The functional modules of 10G Transport Platform include:
TDM 8x GBE or 8x GFC to 10G/OC-192/STM-64
TDM 5x GBE or 5x 2GFC to OC-192/STM-64
TDM 4x OC-48/STM-16 to 10G/OC-192/STM-64
TDM 2x GBE and 2x GFC to OC-48/STM-16
10G transponder with 3R, XFP and fixed Laser Versions
10G protocol converter 10G LAN to 10G WAN (OC-192/STM-64)
DWDM MUX/DeMUX, OADMs, EDFAs
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
MICROSENS
Vista de página 0
1 2 3 4 5 6 ... 70 71

Resumo do Conteúdo

Página 1 - MICROSENS

19'' 6U ChassisOverview6U Chassis is a part of MICROSENS 10G Transport Platform, a high performance andflexible carrier-class transmission s

Página 2 - Features

19'' 6U Chassis page 10/71Figure 9: MS430502M chassis Front view.Installing the MS430502M chassisRack mount InstallationSecurely attach one

Página 3

19'' 6U Chassis page 11/71Figure 10: Ground screw location.• Connect the cable(s) provided to a correctly protected -48V supply.Fuse Rating:

Página 4 - MGNT Management Unit

19'' 6U Chassis page 12/71Preventive MaintenanceDust Filter replacement ProcedureThe dust filter should be visually examined on a six month

Página 5

19'' 6U Chassis page 13/71MGNT boards are shipped with the Agent software loaded. Note the versionrequired on your site in the case where th

Página 6

19'' 6U Chassis page 14/71The rescue CLI allows the user to perform all the upgrade procedure described in theCLI documentation.Use the foll

Página 7 - Mechanical Description

19'' 6U Chassis page 15/71FAN Fan Unit The following alarms indicate a problem with the Fan Unit:• mgnt2AlmFansFailure This bit indicat

Página 8

19'' 6U Chassis page 16/71Module maintenanceModule Replacement ProcedureUse the following procedure to replace a MS module:This procedure is

Página 9 - Installation Manual

19'' 6U Chassis page 17/71ms43062XMRinvSfpTableLocation: ...\microsens\modulems43062XM\ms43062XMri\• Use you SNMP browser to check if there

Página 10

19'' 6U Chassis page 18/71SFP Replacement Procedure on MS43062XMEach Client port has its own LED located on the front panel of the MS module

Página 11

19'' 6U Chassis page 19/71• Clean Fibre Optic connectors on fibre optic cable• Re-connect Fibre• Verify correct operation of the SFPEnd proc

Página 12 - Corrective Maintenance

19'' 6U Chassis page 2/71IntroductionThe MS430502M chassis which is capable of hosting up to ten aggregation andtransport MS modules. The MS

Página 13

19'' 6U Chassis page 20/71 ...\microsens\moduleMS430601M\ms430601mcontrolsWrite\ms430601mCtrlLine\ ms430601mCtrllineSfpOnO

Página 14

19'' 6U Chassis page 21/71• Check the inventory to verify type of XFP currently installed. Consult theobject:ms43062XMRinvXfpLocation: ...\m

Página 15

19'' 6U Chassis page 22/71SNMP User ManualInitial Set-Up and ConfigurationConfigurationConnecting to the managerThe MS430502M chassis contai

Página 16

19'' 6U Chassis page 23/71• Automatic with DIP switchesThe MS430502M chassis MGNT Management Board is equipped with 8 DIPswitches that may

Página 17

19'' 6U Chassis page 24/71To the value xxx.yyy.zzz.1, where xxx.yyy.zzz defines the MS430502M chassis IPAddress map.2. Configure the DIP swi

Página 18

19'' 6U Chassis page 25/71performed using a ping function. The estimated time to detect a dead gateway is lessthan 30 seconds.The table• mgn

Página 19

19'' 6U Chassis page 26/71The object mgnt2GigmRwCommunity is not readable. The returned value is always“*******”.• mgnt2GigmTrapCommunity, d

Página 20

19'' 6U Chassis page 27/71Version Number: 06Release date (yymmddww):06101241mgnt2RinvLinuxAgent identification.Example Response:Linux Part N

Página 21

19'' 6U Chassis page 28/71mgnt2AlmMsSlot6AbsentMS present in Chassis slot 6: This OID indicates the presence of a MSmodulein Slot 6 of the C

Página 22 - SNMP User Manual

19'' 6U Chassis page 29/71file must be cleared to insure correct logfunctionfunctionmgnt2AlmLog80FullLog File Full Warning :This OID indicat

Página 23

19'' 6U Chassis page 3/71Figure 1: Management cards and generic slots organisation.The ten additional generic slots available in the MS43050

Página 24

19'' 6U Chassis page 30/71Name Description ValueAPI Information CodesDEF_API_OK Default Value 0DEF_API_COLD_RESET_MODULE Cold Reset request

Página 25

19'' 6U Chassis page 31/71Software ManagementMIB location:...\microsens\mgnt2\mgnt2SoftwareManagement\In all the following procedures, the u

Página 26

19'' 6U Chassis page 32/71When renaming the package ensure that the new name is compliant with theUnix standard and no more than 24 characte

Página 27

19'' 6U Chassis page 33/71And which one is currently being extracted by the variable:mgnt2ExtractedPack• Check the presence of the required

Página 28

19'' 6U Chassis page 34/71• Progress indicator:The value of: mgnt2PackageExtractionInProgressCan be consulted to monitor the progress of the

Página 29

19'' 6U Chassis page 35/71Procedure1. Remote Loading PhaseThe object of this phase is to load the software package into the RAM of theMS4305

Página 30

19'' 6U Chassis page 36/71• Check that your package is loaded correctly by consulting the table:mgnt2DwlUploadingTableLocation:...\microsens

Página 31

19'' 6U Chassis page 37/71In the event of an incorrect completion of this phase see FallBack 2 for reverse procedure. (Fall Back Procedures)

Página 32

19'' 6U Chassis page 38/71Associated with the package to be erased.If the package that you intend to erase from the FLASH is in use, i.e.:mg

Página 33

19'' 6U Chassis page 39/71T:\home\> tftp -i 192.168.16.123 PUT xxx.ext /tftpboot/yyy.extWhere: T:\home – is the location of the code on y

Página 34

19'' 6U Chassis page 4/71Figure 2: MS430502M chassis General Block diagram.MGNT Management UnitThe block diagram of the MGNT unit is given i

Página 35

19'' 6U Chassis page 40/71msXXXXXXXDwlgwBanksUsed• Gateware :msXXXXXXXDwlGwBank1NotemptymsXXXXXXXDwlGwBank2NotemptymsXXXXXXXDwlGwBank3Notemp

Página 36

19'' 6U Chassis page 41/71 Location: ...\microsens\mgnt2\mgnt2SoftwareManagement\mgnt2LoadMSTable\mgnt2LoadMSEntryBank 1 o r 2 for

Página 37

19'' 6U Chassis page 42/71Normal management operations may be carried out during the transfer, howeverthe response time may be a little slow

Página 38

19'' 6U Chassis page 43/71msxxxxxxxRinvGwPlatformLocation: …\microsens\moduleMsxxxxxxx\msxxxxxxxriVerify that the versions are correct.In th

Página 39

19'' 6U Chassis page 44/71If the package that you intend to erase from the FLASH is in use, i.e.:mgnt2ExtractedPack = "two", this

Página 40

19'' 6U Chassis page 45/71ProcedureFall Back 4In the event of incorrect completion of the Generic slot MS Module Code UpgradeRemote Loading

Página 41

19'' 6U Chassis page 46/71ResetsThe following describes the various methods of resetting the MGNT board.Under no circumstances should a Rese

Página 42

19'' 6U Chassis page 47/71Figure 14: MGNT Management board reset button.Visual indications:The colour sequence of the front panel LEDs are:H

Página 43

19'' 6U Chassis page 48/71• Set the object: mgnt2CtrlChassisShutDownLocation: ...\microsens \mgnt2\mgnt2Hardware \mgnt2controls\• Using a co

Página 44

19'' 6U Chassis page 49/71• Power Up:Connect the -48V supply(s) on the front panel.• Visual indications:The colour sequence of the front pan

Página 45

19'' 6U Chassis page 5/71The main characteristics of the MGNT management unit are:• Processor: 32 bit, 177 MHz• RAM memory: 64 Mbytes• Flash

Página 46

19'' 6U Chassis page 50/71Front view The object:• mgnt2GigmSelectedBoardLocation:…\microsens\mgnt2\mgnt2SNMPAgentData\mgnt2ModulesManagem

Página 47 - End procedure

19'' 6U Chassis page 51/71Upload a configurationA user may upload the configuration of a MSxxxxxxx module to a PC via the MGNTmanagement boa

Página 48

19'' 6U Chassis page 52/71• Use your SNMP browser to check the backup file presence in the FLASHmemory of the MGNT management board using th

Página 49

19'' 6U Chassis page 53/71• Open a Command Line Interface window from your operating system and goto the directory where you want to store t

Página 50

19'' 6U Chassis page 54/71Location:...\microsens\mgnt2\mgnt2ConfigManagement\mgnt2CnfUploadConfigFilesTable• Open a Command Line Interface w

Página 51

19'' 6U Chassis page 55/71Location:...\microsens\mgnt2\mgnt2ConfigManagement\mgnt2CnfUploadConfigFilesTableThis validates the transfer of th

Página 52

19'' 6U Chassis page 56/71The MGNT management board will check the compatibility between the backupconfiguration file and the target MSxxxxx

Página 53

19'' 6U Chassis page 57/71Figure 15: Connecting two MS430502M chassis with 2nd ethernet portIf using a table top mount you can stack up to 5

Página 54

19'' 6U Chassis page 58/71Connect the new MS430502M chassis to the last one installed using an Ethernetcable (straight or crossover)It is ne

Página 55

19'' 6U Chassis page 59/71If the incoming line is transporting the management information on DCC, it is highlyrecommended to disable the DCC

Página 56

19'' 6U Chassis page 6/71If a failure occurs on one of the two main power converters, it is detected by a failurecircuitry and the protectio

Página 57

19'' 6U Chassis page 60/71AppendixesLaser ClassLaser Class Risks General Requirements1Considered safe to eye and Skin underall reasonably fo

Página 58

19'' 6U Chassis page 61/71MGNT2 MIB descriptionOID Name Access Description1.3.6.1.4.1.20044.7.1 mgnt2SNMPAgentData1.3.6.1.4.1.20044.7.1.1 mg

Página 59

19'' 6U Chassis page 62/711.3.6.1.4.1.20044.7.1.2.1.1 mgnt2GigmBoardEntry n/a Row Definition for theMSs table1.3.6.1.4.1.20044.7.1.2.1.1.1

Página 60 - Appendixes

19'' 6U Chassis page 63/71community:This OIDdefines the communityfor the SNMP Getfunction1.3.6.1.4.1.20044.7.1.8.2 mgnt2GigmRwCommunity r/

Página 61 - MGNT2 MIB description

19'' 6U Chassis page 64/71A is in fail condition onthe Management board1.3.6.1.4.1.20044.7.2.1.0.16 mgnt2AlmMgntDefFuseB rMgnt Fuse B Fail :

Página 62

19'' 6U Chassis page 65/71unit or no rotation setsthe OID1.3.6.1.4.1.20044.7.2.1.24 mgnt2AlmfanPwrMgmnt1.3.6.1.4.1.20044.7.2.1.24.13 mgnt2Al

Página 63

19'' 6U Chassis page 66/71Management Module:This oid triggers a 'warm'reset of the Chassis . Thistype of reset is not trafficaffec

Página 64

19'' 6U Chassis page 67/711.3.6.1.4.1.20044.7.4.1.1.4 mgnt2FileUpload r/wAgent File Upload: ThisOID validates the uploadofthe SNMP agent fro

Página 65

19'' 6U Chassis page 68/71the repository1.3.6.1.4.1.20044.7.4.4.1 mgnt2LoadMSEntry n/aRow definition for theLOAD article table1.3.6.1.4.1.20

Página 66

19'' 6U Chassis page 69/711.3.6.1.4.1.20044.7.4.6.1.2 mgnt2DwlMScraftPkgFileName rPackage File name inFLASH: This OID gives thenameof the MS

Página 67

19'' 6U Chassis page 7/71Interface SpecificationsPower SupplyDC input power range: nominal: -36Vmaximum: -72VMS430502M chassis equipped with

Página 68

19'' 6U Chassis page 70/711.3.6.1.4.1.20044.7.5.2.1 mgnt2CnfManageConfigFilesEntry n/aRow definition for thepackage uploading table1.3.6.1.

Página 69

19'' 6U Chassis page 71/71the Mgnt2 managementmodule1.3.6.1.4.1.20044.7.3.1 mgnt2TrapApi n/aApi error trap with itsnumber1.3.6.1.4.1.20044.7

Página 70

19'' 6U Chassis page 8/71Figure 7: MS430502M chassis mechanical dimension (ETSI flange).Figure 8: MS430502M chassis mechanical dimension (19

Página 71 - Order Information

19'' 6U Chassis page 9/71Installation ManualSite Preparation.Before installation ensure that your site meets the following requirements:Moun

Comentários a estes Manuais

Sem comentários