19'' 6U Chassis page 31/71
Software Management
MIB location:
...\microsens\mgnt2\mgnt2SoftwareManagement\
In all the following procedures, the user has the possibility to delete some files from
the FLASH and/or the RAM memory. It is necessary to delete only one file at a time to
ensure a correct delete process.
Upgrade Procedures
SNMP Agent Update on MGNT
A user may update the on-board SNMP agent from the manager. To achieve this, you
will need:
An SNMP V2C browser. (For reading and updating values in the MIB)
A tftp client.
The SNMP agent update procedure is carried out in three phases:
1. Remote loading of packages via tftp into the MS430502M chassis MGNT
2. Transferring to the MGNT FLASH memory agent partition
3. Installation in the MGNT FLASH memory agent partition
Described in more detail as follows:
Procedure
1. Remote Loading Phase
The object of this phase is to load the software package into the RAM of the
MS430502M chassis MGNT. There are no service implications during this phase.
For this example, the package will be called package1.pak
Preparation
Verify that the package you intend to download into the FLASH is not
already there:
Consult the table: mgnt2DwlPackageTable
Location:...\microsens\mgnt2\mgnt2SoftwareManagement.
This table will list the four packages resident in the FLASH by the
object:
mgnt2DwlPackageFileName
And which one is currently being extracted by the object:
mgnt2ExtractedPack
If the package that you intend to load in the FLASH is present in the table and is
currently in use (mgnt2ExtractedPack = "two") you will have to change the name
of the package which you intend to load, otherwise the current package will be
overwritten. E.g. if package1.pak is currently in use rename your file
package2.pak.