Module maintenance
Module Replacement Procedure
Use the following procedure to replace a MS module:
This procedure is the same for all the MICROSENS module. All the OIDs given in the
following procedure are dedicated to the MS43062XM replacement. These OIDs must
be adapted to fit the module to replace.
Procedure
• Ensure that the correct module is selected for management. Consult the
object:
mgnt2GigmSelectedBoard
Location:
...\microsens\mgnt2\mgnt2SNMPAgentData\ mgnt2ModulesManagement\
• Change if necessary
Front view
• Refresh the module inventory setting the following object:
MS43062XMRinvReloadInventory
Location: ...\microsens\moduleMS43062XM\ms43062XMri\
• Perform a full inventory on the module, using the objects:
ms43062XMRinvModulePlatform
ms43062XMRinvHwPlatform
ms43062XMRinvSwPlatform
ms43062XMRinvGwPlatform
ms43062XMRinvXfp
• And the table: